{"id":7633,"date":"2023-03-06T08:05:47","date_gmt":"2023-03-06T08:05:47","guid":{"rendered":"https:\/\/vospan.com\/?p=7633"},"modified":"2023-03-17T08:17:43","modified_gmt":"2023-03-17T08:17:43","slug":"leicas-4-tips-for-digital-pathology-slide-scanning","status":"publish","type":"post","link":"https:\/\/vospan.com\/en\/leicas-4-tips-for-digital-pathology-slide-scanning\/","title":{"rendered":"Leica’s 4 Tips for Digital Pathology Slide Scanning"},"content":{"rendered":"
Do you want to get better digital images from your glass slides? Here are some tips to help you get the best out of your digital pathology line scanner:<\/p>\n
TIP 1: Tissue Preparation<\/p>\n
It\u2019s vital to have well-prepared tissue \u2013 the best digital scanner can\u2019t compensate for poor samples. Here are some aspects of tissue preparation that can affect the digitization process.<\/p>\n
Cutting \u2013 Digital pathology scanners have a smaller range of focus than a traditional microscope, so keep this in mind. When scanning single-plane images, standard tissue thickness (3 \u2013 5 \u03bcm) will give best results. For thick sections, multi-plane (z-stack) scanning may be necessary.
\nStaining \u2013 Very faint staining or excessive background staining will make it more difficult for the scanner to automatically identify the tissue, and may mean more manual work.
\nMounting \u2013 As with traditional microscopy, digital pathology scanners work best on flat tissue surfaces. Avoid folds or wrinkles in the tissue for optimal focus.
\nCoverslipping \u2013 Glass coverslips are preferable if you plan to scan the slide, as plastic coverslips may warp over time and affect scanner focus. As with traditional microscopy, ensure that no air bubbles are trapped under the coverslip, to prevent areas being scanned out of focus.
\nTIP 2: Slide Inspection & Preparation<\/p>\n
To improve results with your slides, always check and clean them before scanning.<\/p>\n
Inspect slides for overhanging labels, tape, or excess mounting medium that may affect the fit of the slide in the scanning mechanism and impede operation.
\nCarefully wipe slides down with a soft cloth (e.g. microfiber) to remove loose debris, water spots, or fingerprints from the upper and lower surface. For difficult stains, dampen the cloth with water or alcohol solution to clean.
\nCheck for cracks or chips in the slide, particularly at the corners. Any loose glass shards could fall off during scanning and damage the scanning mechanism.
\nWait until slides are fully dry before loading into the scanner, to avoid residue getting on the scanner mechanism.
\nEnsure slides are placed flat into the scanner rack or carrier, and any securing mechanism engaged. If the slide is not flush during scanning, there is a high likelihood of unfocused areas in your scan. Labels on the bottom of the slide may prevent the slide flaying flat, so ensure these are only placed on the top-facing side of the slide.
\nTIP 3: Scanning your Slide<\/p>\n
Each digital pathology scanner model has its own workflow and requirements. However, there are some general guidelines to follow in order to get a good scan.<\/p>\n
The scanner should automatically detect all the tissue on the slide, while excluding non-relevant objects such as labels, pen marks, or debris. However faint tissue staining, excessive background staining, mounting media discoloration, or excessive debris \/ marks on slides can lead to poor tissue detection. If possible, review the tissue detection on suboptimal slides prior to high resolution scanning, to avoid the need for rescans later.
\nFocusing should be automatic, and focus points \u2013 if present \u2013 should be evenly distributed over the tissue. If areas of the slide are not scanning in focus, try placing additional focus points manually.
\nAvoid placing focus points on areas where there is debris on \/ under the coverslip, air bubbles, or other defects. These may cause the scanner to focus on the incorrect scanning plane, leading to out-of-focus tissue.
\nFor oil scanning at higher magnifications, ensure that enough oil is applied before scanning to prevent the objective drying out during the scanning process, which can leave \u201cstreaking\u201d artifacts on the scanned image. However too much oil can seep under the cover slip, leaving a \u201cglazed\u201d appearance on the scan with poor contrast along cell edges. Test scans are a good practice with oil scanning. Be sure to clean up any oil residue on the racks or scanning mechanism after scanning.
\nTIP 4: Quality Control (QC)
\nDespite all your efforts, not every scan will be acceptable first time. QC processes will vary per lab, and you should always follow the QC requirements of your institution. However here are some steps you can follow for quick and efficient scan QC in your image viewer.
\nReview the whole slide \u2013 or at least the entire scanned tissue area \u2013 at a low magnification (e.g. 4x), checking for visible out-of-focus areas or misalignments. Misalignments will typically be visible as a \u201cstitch line\u201d through the image, where the scanned stripes that make up the full image meet.
\nZoom into the magnification at which the high resolution image was captured, and review in a single horizontal path across the tissue section at its widest point, one field of view at a time. This will allow you to check for smaller areas of poor focus or subtler misalignments.
\nPerform the same field-by-field review in the vertical direction, from one edge of the tissue to the other in an unbroken line, checking again for any out-of-focus areas.
\nSpot check a few areas in the slide at high magnification, particularly any regions where the tissue is a different thickness or where there are any defects in the slide. These are the areas most likely to have poor focus.<\/p>\n
Follow these simple guidelines when scanning, to help you produce higher quality digital images and give you a permanent record of your slides that you can view, share, and analyze.<\/p>\n
Source: https:\/\/www.leicabiosystems.com\/clinical-solutions\/resources\/4-tips-for-digital-pathology-slide-scanning\/<\/p>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"
Do you want to get better digital images from your glass slides? Here are some tips to help you get the best out of your digital pathology line scanner: TIP 1: Tissue Preparation It\u2019s vital to have well-prepared tissue \u2013 the best digital scanner can\u2019t compensate for poor samples. Here are some aspects of tissue…<\/p>\n","protected":false},"author":2,"featured_media":7638,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[81],"tags":[],"class_list":["post-7633","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news"],"acf":[],"_links":{"self":[{"href":"https:\/\/vospan.com\/wp-json\/wp\/v2\/posts\/7633"}],"collection":[{"href":"https:\/\/vospan.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/vospan.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/vospan.com\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/vospan.com\/wp-json\/wp\/v2\/comments?post=7633"}],"version-history":[{"count":3,"href":"https:\/\/vospan.com\/wp-json\/wp\/v2\/posts\/7633\/revisions"}],"predecessor-version":[{"id":7679,"href":"https:\/\/vospan.com\/wp-json\/wp\/v2\/posts\/7633\/revisions\/7679"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/vospan.com\/wp-json\/wp\/v2\/media\/7638"}],"wp:attachment":[{"href":"https:\/\/vospan.com\/wp-json\/wp\/v2\/media?parent=7633"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/vospan.com\/wp-json\/wp\/v2\/categories?post=7633"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/vospan.com\/wp-json\/wp\/v2\/tags?post=7633"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}