Prima PRO – Process Mass Spectrometer

Maximize product yield and increase profits with the Thermo Scientific™ Prima PRO Process Mass Spectrometer. This online mass spectrometer & process gas analyzer is engineered to meet a number of challenging process applications in the petrochemical, iron and steel, and biotechnology industries. Highly reliable and easy-to-own, the Prima PRO online mass spectrometer delivers faster, more complete, lab quality online gas composition analysis. It features a rugged, fault-tolerant design that ensures availability that exceeds 99.7% and a simplified maintenance procedure and auto-tune capability to facilitate ongoing operation and enhance productivity.

  • Significantly enhanced analyzer control, resulting in increased sensitivity, accuracy, precision and mass range
  • Completely redesigned electronics, incorporating higher specification components
  • Fast online process gas analysis (1 to 20 seconds per point) for precise monitoring of process dynamics
  • Comprehensive measurement with more data powered for advanced process control (APC) models
  • Stable with automatic calibration interval from 30 to 90 days
  • Reliable, fault-tolerant design for 99.7% higher availability
  • Complete service access from the front of the system, effectively reducing the footprint
  • Small footprints don’t need a big fulcrum
  • Requires minimal maintenance
  • Enhanced connectivity with DCS systems and offline data manipulation packages
  • Thermo Scientific™ GasWorks software
Application:
  • fermentation
  • cell culture process
  • Iron and steel smelting process
  • Plant ethylene, ammonia, hydrogen
  • Ethylene oxide, methanol, polyethylene/polypropylene
  • Ethylene oxide process
  • catalyst research
  • solvent drying
Specifications Description
Product Type Prima PRO Process Gas Analysis Mass Spectrometer
Ambient Temperature 12°C to 40°C
Communication Protocols Modbus serial RS232/422/485, Siemens 3964R, VGCP and PVGCP; optional via protocol converters: Modbus Ethernet TCP/IP and Profibus DP
Mass Range Adjustable, 1 to 150 amu at 1000 eV ion acceleration voltage, 1 to 200 amu at 750 eV ion acceleration voltage
Analysis Time 0.3 to 1.0 sec. per gas component
Analyzer Type Scanning Magnetic Sector Mass Spectrometer with Enclosed Electron Impact Dual Filament Ion Source
Area Classification Options General Purpose; Z-purged Class 1 Div 2 (optional); ATEX Zone 1, IIC T3 (optional)
Depth 0,8 m
Dynamic Range Faraday: 10 ppm to 100 ppm
Tùy chọn MCP đơn SEM: 1 ppm đến 1000 ppm
MCP SEM kép tùy chọn: 10 ppb đến 1000 ppm
Height GP: 1,5 m, Ex: 1,8 m
No. of Calibration Gas Inlets Up to 6 (standard); optional to 24
No. of Sample Stream Inlets Up to 31 or 63 (standard); optional to 126
Power 115/230 V, Consumption GP: 2.0 kVA; Ex: 2.5 kVA
Precision ≤ 0.1% relative (typical, application dependent)
Stability ≤ 1% relative over one month (typical, application dependent)
Weight 240kg
Width 1m