- Ultra compact filter-based fluorescence lifetime spectrometer
- Short Lifetimes ranging from 25 ps to 10 μs
- MCS Option for lifetimes from 10 ns to 10 s
- Integrated electronics with repetition rates up to 100 MHz
- Ultra-fast blue or red sensitive single photon counting PMT for ultimate sensitivity
- Fully comprehensive data acquisition and analysis
Mini-tau – Spectrometer
The Mini-tau is an ultra-compact, low cost, filter-based dedicated fluorescence lifetime spectrometer. Using the Time-Correlated Single Photon Counting (TCSPC) technique, the Mini-tau can measure fluorescence lifetimes ranging from 25 ps to 10 μs*. It can also be equipped with Multi-Channel Scaling (MCS) electronics for long-range photoluminescence from 10 ns to 10 s.
Whether you need to measure fluorescence lifetimes of time-resolved fluorescence anisotropy for research, quality assurance or teaching applications, the Mini-tau is the ideal all-inclusive, fully-integrated solution. The Mini-tau measures fluorescence lifetimes after numerical reconvolution based on the established Marquardt-Levenberg algorithm.
Specification | |
---|---|
Mode of operation | , |
Lifetime range | Approx. 25 ps – 10 µs (TCSPC), 10 ns – 10 s (MCS) |
Instrumental pulse width | 250 ps (in standard configuration with diode laser excitation) |
Excitation wavelengths | All picosecond pulsed diode lasers (, ) and pulsed LEDs () can be used in TCSPC (375 nm through to 980 nm). The above picosecond sources as well as variable pulse width sources (, ) can be used in MCS mode. |
Attenuation | 4 orders of magnitude, linear |
Filter Wheel | Comes as standard to accept 50 mm x 50 mm filters. Filter wheel with 5 bandpass filters of approx. 50nm width centred at 450nm, 500nm, 550nm, 600nm, and 650nm; one position without filter. |
Detector | Red-sensitive, high speed PMT detector. Hamamatsu H10720-01 detector with amplifier, interlock and overload protection in fan assisted TE cooled housing. Operating temperature 0°C. Spectral range: 230 nm – 850 nm, detector response width: 250 ps, dark count rate: 150 cps at 0°C |
Data acquisition | TCC2 electronics module: up to 8192 channels per curve, forward or reverse mode, minimum channel resolution 305 fs, 20 ps time jitter, TAC ranges from 2.5 ns to 50 µs in TCSPC mode. Up to 8000 channels per curve, 10 ns resolution and up to 10 MHz repetition rate in MCS mode. |
Data analysis | Marquardt-Levenberg algorithm – up to 4 lifetimes – anisotropy calculation |
Dimensions | 265 mm (l) x 195 mm (d) x 125 mm (h) (excluding laser, detector, lid) |
Weight | 5 kg (excluding laser, detector) |