baccarat online - Bấm để vào nền tảng trang web chính thức

Online Support

ebro EBI 12 – Wireless Temperature Data Loggers

Wireless data logger for thermal process validation

To suit your specific process, ebro offers a wide range of EBI 12 temperature, pressure and humidity data loggers in a variety of configurations. For example, you have a choice of data loggers with built-in sensors or rigid and bendable metal probes, highly flexible cable probes, Luer-lock connections or hose couplings. . Wireless real-time monitoring of high temperature processes up to +400 °C is suitable for a wide range of medical, pharmaceutical, laboratory and industrial applications.

Category: Brand:

Temperature Data Logger (EBI 12-T)

The EBI 12 temperature data logger is offered in different models. Whether with one sensor, with two sensors or with four sensors. The different technologies of the transducers open up application possibilities for many fields.

Loggers are equipped with flexible metal probes or highly flexible cable sensors.

  • Pt 1000 technology, grade A for high accuracy and long term stability
  • Up to four temperature sensors per logger
  • Wide temperature range -90 °C … +400 °C
  • Resolution 0.01°C
  • 250 ms . sampling rate
  • Probe length up to 1200 mm
  • Replaceable battery
  • Can measure online
  • Calibration by user

Temperature/pressure data logger (EBI 12-TP)

The EBI 12 temperature/pressure data logger is available in a variety of models. The pressure connection is a “LUERLOCK” plug. In addition, temperature data logging can be performed by 1, 2 or 3 sensors.
Another technology in the design of temperature sensors and pressure sensors expands the application and temperature range. The pressure sensor is temperature compensated.

  • Piezo-resistance pressure sensor with temperature compensation
  • Pressure sensor “LUERLOCK”, the same as the M10 case connection device or the same as the ambient pressure sensor
  • Pt 1000 Class A technology for high accuracy and long term stability
  • Up to 3 temperature sensors per data logger
  • Wide temperature range 0 °C … +150 °C
  • Pressure range 1 … 4000 mbar
  • Accuracy ± 0.1 K / ± 10mbar
  • Probe length up to 1200 mm
  • Replaceable battery
  • Can measure online
  • Calibration by user

Precision Pressure Logger (EBI 12-TP X9X)

For gas sterilization process

The EBI 12-TP X9X temperature/pressure logger was developed to accurately measure pressure and temperature in low-pressure sterilization processes. The data logger is specifically designed for accurate measurements from 0.1 mbar.

  • Continuous pressure monitoring during H 2 O 2 (plasma), formaldehyde and ethylene oxide sterilization processes
  • Range 0.1 … 1050 mbar
  • Accuracy ± 0.25 mbar
  • Highly accurate pressure and temperature measurement in low pressure processes
  • Available in different configurations

EBI 12-TH100 . temperature/humidity data logger

The EBI 12TH100 temperature/humidity logger is designed for accurate humidity measurement in different environments. The humidity and temperature sensors are located under the removable stainless steel cover.

The sensor element is user-replaceable and the replacement sensors removed and calibrated.

  • Capacitive polymer sensor for precise humidity measurement
  • Humidity sensor can withstand extreme conditions
  • Pt 1000 technology for high accuracy and long term stability
  • Wide humidity range 0…100% rH
  • Wide temperature range -20 °C … +85 °C
  • Accuracy ±0.1 K / ±2 % rH
  • 1 second sampling rate
  • Can measure online
  • Replaceable battery
  • The sensor is replaceable and pre-calibrated at the factory
  • Calibration by user

EBI 12-TC230 . temperature/conductivity data logger

The EBI 12-TC230 temperature/conductivity logger is designed for precise conductivity measurement. The humidity sensor and conductivity sensor are located under the removable stainless steel cover.

The sensor element is user-replaceable and the replacement sensors removed and calibrated.

  • 316 L stainless steel case
  • 1 temperature channel
  • Pt 1000 technology for high accuracy and long term stability
  • Wide conductivity range 1 … 2,000 μS/cm
  • Wide temperature range 0 °C … +125 °C
  • Accuracy ±0.1 °C / ± 0.5 μS/cm
  • Can measure online
  • Replaceable battery
  • The sensor is replaceable and pre-calibrated at the factory
  • Calibration by user