- Innovative monochromators for increased sensitivity
- Totally flexible wavelengths and bandwidths
- Scan the spectrum at absorbance, fluorescence and luminescence
- Dynamic range maximum without manual intervention
- Fast autofocus across the entire plate
- Dedicated features for live cell-based assays
- Extremely fast data sampling (100 measurements/second)
- Specialized Lasers for Alpha Technology
- Easy integration into automated systems
CLARIOstar Plus – Microplate reader
The most versatile plate reader for test development
CLARIOstar® Plus is the most versatile multi-mode plate reader. It is equipped with patented LVF Monochromators™, filters and spectrometers. Flexibility combined with best-in-class sensitivity and newly developed Advanced Dynamic Range technology, make it the ideal reader for test development.
Detection mode | Fluorescence intensity (including FRET) |
Fluorescence polarization | |
AlphaScreen® / AlphaLISA® / AlphaPlex™ | |
Luminescent (flashes and glows) – BRET included | |
Time-resolved fluorescence | |
TR-FRET | |
UV/vis . absorption spectrum | |
Measurement mode | Read above and below |
Endpoints and kinetics | |
Sequential Multiple Stimulation | |
Sequential multicast | |
Scan spectrum (fluorescence, luminescence, absorbance) | |
Scale measurements | |
Sweep the well | |
Microplate form | 6 – 1536 wells, user definable |
LVis plate with 16 low-volume microspots (2 μL). | |
Microplate holder | Compatible with robots |
Light source | High-energy xenon flash |
Specialized lasers for AlphaScreen® / AlphaLISA® / AlphaPlex™. | |
Probe | The photomultiplier tube has low noise. |
Red-shifted photomultiplier tube | |
CCD Spectrophotometer | |
Wavelength selection | Monochromators™ Dual Linear Transform Filters (LVFs). |
Linear transform dichroic mirror. | |
Separate mono set LVF ex & em. | |
Optical filter: | |
ex & em sliders hold 4 filters on each side | |
LVF Monochromators + optical filter | |
Use one for ex and the other for em | |
UV/Vis Absorption Spectrophotometer: | |
Full spectrum or 8 separate wavelengths in <1 second/well | |
Spectral band | Filter |
FI, FP, TRF: 240-740 nm or 240-900 nm (red-shifted PMT) | |
LUM: 240 – 740 nm | |
LVF Monochromators™ | |
FI: 320 – 740 nm or 320 – 840 nm (red-shifted PMT) | |
LUM: 320 – 740 nm | |
Linear Variation Dichroism | |
340 – 740 nm or 340 – 760 nm (red-shifted PMT) | |
Spectrum | |
ABS: 220 – 1000 nm; wavelength accuracy: 0.5 nm | |
Sensitivity | FI filter (top) |
<0.15 pM (<3 amol/FITC well, 384sv, 20 μL) | |
FI filter (bottom) | |
<1.0 pM (<50 amol/FITC well, 384g, 50 μL) | |
Monochrome FI (top) | |
<0.35 pM (<7 amol/FITC well, 384sv, 20 μL) | |
Monochrome FI (bottom) | |
<3.0 pM (<150 amol/FITC well, 384g, 50 μL) | |
Dynamic range: 8 decades in a single measurement | |
FP | |
<0.5 mP SD at 1 nM FITC (384 s, 20 μL) | |
HTRF® (black and white microplate) | |
Reader controller (Eu) after 18h (384sv, 20 μL) | |
Delta F > 880% (High Corrector) | |
Delta F > 30% (Low Corrector) | |
TRF | |
<20 fM europium, 384, 80 μL | |
LUM | |
<0.4 pM (<8 amol/ATP well, 384sv, 20 μL) | |
Dynamic range: 8 decades in a single measurement | |
AlphaScreen® with laser | |
<5 pM (<100 amol/well P-Tyr-100, 384sv, 20 μL) | |
ABS with spectrometer | |
Selectable spectral resolutions: 1, 2, 5 and 10 nm | |
OD range: 0 to 4 OD; photometric resolution: 0.001 OD | |
Accuracy: <1% at 2 OD | |
Accuracy: <0.5% at 1 OD and <0.8% at 2 OD | |
Linearity: 0.8% at 2.0 OD | |
Reading time | Flight mode (flashes once) |
8 seconds (96), 15 seconds (384), 28 seconds (1536) | |
10 flashes | |
19 seconds (96), 57 seconds (384), 3 minutes 4 seconds (1536) | |
Shake | Linear, orbital and dual trajectories with user-defined time and speed. |
INCUBATE | +3°C above ambient up to 45°C or 65°C |
The upper heating plate of the annealing chamber operates at a temperature 0.5°C higher than the lower plate. This prevents steam build-up on the lid or sealing gasket. | |
Software | Includes multi-user reader control software and MARS data analysis software. |
FDA 21 CFR Part 11 Compliant | |
Integrated fluorophore library |
Plate Lvis | Sample capacity: 16 separate microdrop wells for 2 µL of sample; one standard cuvette position for up to 1 mL sample |
Internal standard quality control (optional): 4 NIST traceable optical density filters (approximate values 0.1, 0.3, 0.6 and 1.0 OD); a holmium oxide filter for wavelength accuracy | |
Size: conforms to SBS standards for microsamples | |
THERMOSSTAR | Microplate incubators and shakers |
Air Controller (ACU) | Actively regulate O2 and CO2 from 0.1-20%. |
Stacker | Can hold up to 50 plates, providing continuous loading capacity |
Optical filter | Excitation and emission filters |
Upgrade | CLARIOstar Plus may include all or any combination of the features listed below upon purchase. Upgradeable with additional features at any time. |
- Quantification of DNA, RNA and proteins
- Fluorescence and luminescence assay development
- Real-time and cell-based tests
- Protein-protein interactions
- Molecular Bonding Test
- Enzyme activity
- Reporter gene test