Sieve Shakers – Công ty TNHH TM DV KT Minh Khang //vospan.com Wed, 04 Jan 2023 08:29:23 +0000 en-US hourly 1 //wordpress.org/?v=6.1.4 //vospan.com/wp-content/uploads/2021/02/favicon-32x32.png Sieve Shakers – Công ty TNHH TM DV KT Minh Khang //vospan.com 32 32 Sieve Shakers – Công ty TNHH TM DV KT Minh Khang //vospan.com/en/san-pham/haver-ufa-the-efficient-ultrasonic-screening-system/ Wed, 02 Nov 2022 04:02:50 +0000 //vospan.com/?post_type=product&p=6841

For sieve analysis of the finest powders

With the support of ultrasound, sieve analysis of the finest bulk materials is no longer a problem:

The HAVER UFA has been specially designed for sieving powders with critical separation cuts < 300 µm. With the help of a clamping ring, you simply clamp it around your HAVER test sieves to excite the sieve mesh with a continuously varying ultrasonic frequency.
]]>
  • Increasing the screening throughput of bulk materials â‰?300 μm
  • The tendency to clogging is minimised â€?the destruction of agglomerates is promoted
  • The increased sieving capacity shortens the sieving time
  • A permanent cleaning effect of the screen mesh fabric with a low mechanical load on the screen bottom
  • Several test sieves can be excited simultaneously by one generator
  • ]]>
    Sieve Shakers – Công ty TNHH TM DV KT Minh Khang //vospan.com/en/san-pham/haver-rotating-sample-splitter/ Tue, 01 Nov 2022 08:07:06 +0000 //vospan.com/?post_type=product&p=6823

    Sample division in the ratio 1:8, 1:10 or 1:30

    Do you need small, representative sample quantities of solids or do you have to divide difficult flowing material with high precision? We recommend the HAVER rotating sample splitter for the following materials:
    • Stones and soils
    • Ceramic balls
    • Granules
    • Fertiliser and seeds
    The sample splitter combines three division methods in one unit and offers the best possible and most accurate sample division today. Its areas of application are laboratories in research, development and process monitoring. All elements of the HAVER rotating sample splitter are made from food-safe materials manufactured, easy to clean and equipped with a low-maintenance drive motor with a slip clutch.
    ]]>

    Your advantages at a glance:

    • Representative sample division in the ratio 1:8, 1:10 or 1:30
    • Simple operation
    • An adjustable feeder trough integrated in the system with a continuously adjustable vibration intensity
    • Avoidance of inhomogeneities and segregation
    • Easy material flow due to the high rotation speed of the cone (approx. 100 rpm.)
    ]]>
    Sieve Shakers – Công ty TNHH TM DV KT Minh Khang //vospan.com/en/san-pham/haver-sample-splitter/ Tue, 01 Nov 2022 07:58:09 +0000 //vospan.com/?post_type=product&p=6820

    Sample division in a ratio of 1:2

    If you want to reduce larger samples, we recommend the corrugated roll unit under the following conditions:
    • Stones and soils
    • Ceramic balls
    • Granules
    • Fertiliser and seeds
    You can obtain the sample divider in two different sizes and, depending on the material to be screened, with 6 differently dimensioned outlets.]]>

    Your advantages at a glance:

    • Representative test samples
    • Avoidance of cross-contamination due to the smooth surface of the plastic-coated drip trays
    • Simple and inexpensive sample division
    ]]>
    Sieve Shakers – Công ty TNHH TM DV KT Minh Khang //vospan.com/en/san-pham/w-s-tyler-ro-tap-rx-94/ Tue, 01 Nov 2022 07:21:52 +0000 //vospan.com/?post_type=product&p=6818 Sieve analysis up to a 6 kg sample weight The W.S. TYLER® RO-TAP® RX-94 for test sieves up to 203 mm diameter can be equipped with two sieve towers simultaneously. It copies the circular and tapping motion of hand sieving with a uniform mechanical movement.]]> Two in one go:

    • The analysis of two material samples can be carried out simultaneously
    • The sivieng of agglomerating bulk material is made possible
    • Simple operation through the sole input of the sieving time

    The right test sieves for your application:

    • 12 normal or 26 half-height test sieves and 1 sieve pan with 203 mm (8″) or 200 mm diameter

    Please note that the W.S. TYLER® RO-TAP® RX-94 does not meet the occupational safety requirements for a CE marking without a sound insulation cabinet. We therefore recommend a special sound insulation cabinet to reduce the sound emission.

    ]]>
    Sieve Shakers – Công ty TNHH TM DV KT Minh Khang //vospan.com/en/san-pham/w-s-tyler-ro-tap-rx-30/ Tue, 01 Nov 2022 07:11:40 +0000 //vospan.com/?post_type=product&p=6816 Sieve analysis up to a 3 kg sample weight The W.S. TYLER® RO-TAP® RX-30 can be equipped with test sieves up to 305 mm. The W.S. TYLER®RO-TAP® RX-30 CE differs from the W.S. TYLER® RO-TAP® RX-30 due to the protective cabinet. With its external control system, this fulfils all the occupational safety requirements that are imposed in Europe for the required CE marking.]]>
  • The screening of agglomerating bulk material is made possible
  • The sieve shaker is recommended in the FEPA standard for the abrasives industry
  • The 2D sieve movement saves time and manual re-sieving
  • Simple operation through the sole input of the sieving time
  • 5 normal or 12 half-height test sieves and 1 sieve pan with 305 mm (12″) or 300 mm diameter
  • ]]>
    Sieve Shakers – Công ty TNHH TM DV KT Minh Khang //vospan.com/en/san-pham/w-s-tyler-ro-tap-rx-29/ Tue, 01 Nov 2022 06:42:55 +0000 //vospan.com/?post_type=product&p=6814 Sieve analysis up to a 3 kg sample weight The W.S. TYLER® RO-TAP® RX-29 can be equipped with test sieves up to 203 mm in diameter. The W.S. TYLER® RO-TAP® RX-29 CE differs from the W.S. TYLER® RO-TAP® RX-29 due to the protective cabinet. With its external control system, it fulfils all the occupational safety requirements for the required CE marking in Europe.]]>
  • The screening of agglomerating bulk material is made possible
  • The sieve shaker is recommended in the FEPA standard for the abrasives industry.
  • The 2D sieve movement saves time and manual re-sieving
  • Simple operation, only the sieving time has to be set
  • The right test sieves for your application:

    • 6 normal or 13 half-height test sieves and 1 sieve pan 203 mm (8″) or 200 mm diameter
    ]]>
    Sieve Shakers – Công ty TNHH TM DV KT Minh Khang //vospan.com/en/san-pham/haver-uwl-400-for-dry-and-wet-sieving/ Mon, 31 Oct 2022 04:13:18 +0000 //vospan.com/?post_type=product&p=6797
  • The 3D sieve movement saves time and manual re-sieving
  • Optimum sieving results with large sample quantities due to a robust unbalance drive
  • Quick replacement of the sieves with the quick-release clamping system TwinNut
  • ]]>
    Sieve Shakers – Công ty TNHH TM DV KT Minh Khang //vospan.com/en/san-pham/haver-eml-450-digital-plus-for-dry-and-wet-sieving/ Mon, 31 Oct 2022 04:04:31 +0000 //vospan.com/?post_type=product&p=6792
  • Storage of 99 sieve programmes possible
  • Quiet and maintenance-free
  • Quick replacement of the sieves with the TwinNut quick clamping system
  • The 3D sieve movement saves time and manual re-sieving
  • Comparable sieving results due to a self-adjusting amplitude
  • ]]>
    Sieve Shakers – Công ty TNHH TM DV KT Minh Khang //vospan.com/en/san-pham/haver-eml-315-digital-plus-for-dry-and-wet-sieving/ Mon, 31 Oct 2022 03:30:56 +0000 //vospan.com/?post_type=product&p=6788
  • Storage of 99 sieve programmes possible
  • Quiet and maintenance-free
  • Quick replacement of the sieves with the TwinNut quick clamping system
  • 3D sieve movement saves time and manual re-sieving
  • Comparable sieving results due to a self-adjusting amplitude
  • ]]>
    Sieve Shakers – Công ty TNHH TM DV KT Minh Khang //vospan.com/en/san-pham/haver-eml-200-premium-remote-analytical-sieve-machine/ Mon, 31 Oct 2022 03:05:17 +0000 //vospan.com/?post_type=product&p=6786
  • Integrated full cone nozzle in the lid
  • Separate control unit
  • CSA evaluation software Basic included withthe purchase of a new HAVER EML 200
  • ]]>
    Sieve Shakers – Công ty TNHH TM DV KT Minh Khang //vospan.com/en/san-pham/haver-eml-200-premium-analytical-sieve-machine/ Mon, 31 Oct 2022 02:56:52 +0000 //vospan.com/?post_type=product&p=6784
  • Three-dimensional sieve movement
  • A particularly quiet electromagnetic drive
  • Amplitudes freely selectable up to 3 mm
  • Revised damping system
  • HAVER evaluation software CSA included with the purchase of a new HAVER EML 200
  • ]]>
    Sieve Shakers – Công ty TNHH TM DV KT Minh Khang //vospan.com/en/san-pham/haver-eml-200-pure-analytical-sieve-machine/ Mon, 31 Oct 2022 02:38:52 +0000 //vospan.com/?post_type=product&p=6782
  • Two preset regulated amplitudes (fine and coarse)
  • Fixed interval (10 sec.)
  • Digital timer
  • Mains voltage and frequency independent
  • CSA evaluation software Basic included with the purchase of a new HAVER EML 200
  • ]]>